- Overview
- Product Description
- Detailed Photos
- Product Parameters
- Our Advantages
- Company Profile
- FAQ
Basic Info.
Model NO.
ATS Dual Power Distribution Box
Form
All- packaged Type
Operation Voltage
Low Voltage
Size
3/2 Uint
Application Range
Oil
Shell Material
Aluminum Alloy
Shell Protection Grade
IP23
Brand
Green Storage
Product Name
ATS Dual Power Distribution Box
Keywords
ATS Distribution Box
Installation Method
Indoor Installation
Rated Voltage
400V
Frequency
50Hz
Rated Current
32A to 3200A
Protection Class
IP54~66
Color
Customized
Application
Electric Power Transmission
OEM or ODM
Available
MOQ
1 Set
Sample
Accept
Transport Package
Export Standard Wooden Case
Specification
80.00cm * 60.00cm * 220.00cm
Trademark
GREEN STORAGE
Origin
Jiangsu, China
HS Code
8537109090
Production Capacity
50000 Sets/Year
Packaging & Delivery
Package Size
23.50cm * 41.00cm * 25.00cm
Package Gross Weight
11.000kg
Product Description
GREEN STORAGE Electrical Equipment Supplier China ATS Dual Power Distribution Box For Farm
ATS Dual Power Distribution BoxThe ATS Type Power Distribution Device Is Suitable For Main Equipment Power Conversion Systems And Is Used As The Main Power Supply Place For Fire Protection, Hospitals, Shopping Malls, Projects, Plateau Buildings, Etc. Where Power Outages Are Not Allowed.
The Dual Power Automatic Transfer Switch Using Domestic And International Advanced ATS Technology Will Not Cause Two Power Sources To Be Connected At The Same Time Even Under Abnormal Circumstances And Can Implement Manual/Automatic Conversion. The Applicable Scope Is a Rated Voltage of 400V, Frequency of 50Hz, And Rated Current From 32A To 3200A. Through Optimized Design, It Has a Small Size, Easy Operation, Beautiful Appearance, Safe And Reliable Use, And Is The Latest Innovation In The New Century.
1. The Altitude Does Not Exceed 2,000 Meters.
2. The Ambient Temperature And Ambient Air Temperature Shall Not Be Higher Than +40°C, The Average Temperature Within 24 hours Shall Not Be Higher Than +35°C, And The Ambient Air Temperature Shall Not Be Lower Than -100°C.
3. There Must Be No Excessive Dust, Acid, Salt, Corrosive And Explosive Gases In The Air. The Relative Humidity Should Not Exceed 50% When The Highest Temperature Is +400°C. A Higher Relative Humidity Is Allowed At The Lowest Temperature, Such As 90% When Below +20°C. It Should Be Considered That Accidental Occurrences Caused By Temperature Changes Should Be Taken Into Account. General Condensation.
4. When Users Have Special Requirements, They Can Negotiate With The Manufacturer
Wiring Diagram
The Main Function
1. Generator Sets, UPS Front-End Power Distribution, EPS Power Supply Front-End Power Distribution, Etc.
2. Important Places Where Power Outage Is Not Allowed, Such As Hospitals, Shopping Malls, Banks, Chemical Industry, Metallurgy And High-Rise Buildings.
3. Water Temperature And Oil Pressure Probes Can Be Configured To Protect The Unit From High Water Temperature And Low Oil Pressure. When The Unit Encounters Low Oil Pressure Or High Water Temperature, The Control Cabinet Will Issue An Alarm And Shut Down The Unit.
4. A Servo Motor Or Electronic Speed Regulator Can Be Configured To Realize The Idle Speed Control Of The Unit: After The Unit Starts, It Will First Increase Speed After The Set Idle Running Time. When The Unit Stops, It Will First Slow Down And Then Run At Low Speed. After The Set Stop After Idle Running Time. Supports Throttle Servo Motor And Electronic Speed Regulator.
5. Parameters Can Be Set To Adapt To The Control Needs Of Different Occasions (The Main Settable Parameters Are System Frequency, Start And Stop Delay Time, Cooling Time, And Preheating Time).
Other Features
1. Adopt Double-Row Composite Contacts, Horizontal Connection Mechanism, Micromotor Pre-Energy Storage, And Microelectronic Control Technology To Basically Achieve Zero Flashover (No Arc Extinguishing Device)
2. Use Reliable Mechanical Interlocking And Electrical Interlocking Technology
3. Adopt Zero-Crossing Technology
4. It Has an Obvious On-Off Position Indication And Padlock Function, Which Can Reliably Realize The Isolation Between The Power Supply And The Load. It Has High Reliability And A Service Life Of More Than 8,000 Times.
5. Mechatronics Design, Switch Conversion Is Accurate, Flexible And Reliable, Good Electromagnetic Compatibility, Strong Anti-Interference Ability, No External Interference, High Automation Program
6. The Fully Automatic Type Does Not Require Any External Control Components.